Wednesday 24 August 2016

Inspecting and Correcting Problems of Water Transfer Pump - 2

In the last blog, we have discussed how you can inspect and correct water transfer pump problems you might have to encounter. There are some problems that can stop the progress of the most household chores and industrial processes. When the pump stops working and there is not any backup, it is important to locate the problem and treat the pump to restore the adequate supply of water. There are some issues in the pump that you can address on your own. However, it is not recommended if you do not know the pump from inside out. If it appears that you cannot repair the pump, calling a professional is a wise move. In continuation of the previous blog, here are some more water transfer pump problems.
Problem
Incorrectly set or stuck pressure regulating valve.

Inspection
Inspect valve setting and look for a defect in the valve.

Solution   
Reset and clean the valve. If it is required to replace the valve, replace it.    
Problem
Leak on well to pump suction

Inspection
If it is a shallow well unit, attach a pressure gauge on the suction side.
In case of deep well system, install the pressure gauge on the pump.
After closing the discharge line valve, apply 30 PSI pressure to the system using an air compressor. Now shut off the compressor. If the system is unable to hold the pressure, there is leakage.            

Solution
Make all above ground connections tight. You might have to pull piping and repair leakage.  
Problem
Low level of water in the well.   

Inspection
Check the depth of the well against the performance of the pump. Also make sure that the ejector of the proper size is used.     

Solution
Replace the ejector or the pump if undersized.
Problem
Combination of the pump and ejector is wrong.

Inspection
Check the ejector and pump model against the performance charts.  

Solution
If the ejector is of wrong model, replace it.  
Problem
Frozen pipes

Inspection
Check the temperature of the pipe.  

Solution
Heat the pit or the pump house.
Problem
Plugged impeller, or defective or worn pump parts.  

Inspection
If the delivery is low, it is because of defective or worn impeller or other part of the pump. Therefore, disassemble and inspect the pump.    

Solution
Repair or replace pump parts.  
Problem
Plugged ejector.  

Inspection
Remove and inspect the ejector.

Solution
Clean the ejector and reinstall it.
Problem
Plugged or defective foot valve.

Inspection
Check the water delivery. If it is low, the foot valve might be partially clogged. If there is no delivery, the foot valve is completely clogged. Pull and inspect the foot valve.

Solution
Clean or repair the foot valve. Replace if required.